BVS 14-66 CATV amplifier 40 dB | 111 dBµV CSO/CTB

PDFPrint
Remote CATV Amplifier
BVS 14-66 CATV amplifier 40 dB | 111 dBµV CSO/CTBBVS 14-66 CATV amplifier 40 dB | 111 dBµV CSO/CTB
BVS 14-66 CATV amplifier 40 dB | 111 dBµV CSO/CTB
BVS 14-66 CATV amplifier 40 dB | 111 dBµV CSO/CTB
BVS 14-66 CATV amplifier 40 dB | 111 dBµV CSO/CTB
BVS 14-66 CATV amplifier 40 dB | 111 dBµV CSO/CTB
Description

 

  • Remote power supply at input/output

  • GaAs technology

  • Downstream 85…1006 MHz

  • Attenuation/equalization adjustable with PCB switches

  • Interstage attenuation/equalization pluggable with jumpers

  • Cable simulator BZU 80-02 pluggable

  • Upstream 5...65 MHz

  • Active/passive pluggable with jumpers

  • Attenuation adjustable with PCB switch

  • Interstage attenuation/equalization pluggable with jumpers

  • Al-die-cast housing

  • Test ports at in- and output

 

EMC according to EN 50083-2, class A

Downstream
Frequency range 85…1006 MHz
Gain 40 dB
Max. output level CSO/CTB (CENELEC raster, 41 channels, 60 dB IMA) 111 dBµV
Attenuation: adjustable in 1 dB steps 0…15 dB
Equalization: adjustable in 1 dB steps 0…15 dB
Attenuation interstage: pluggable with jumpers 0 | 2 | 4 | 6 dB
Equalization interstage: pluggable with jumpers 0 | 2 | 4 | 6 dB
Return loss ≥ 18 dB (-1.5 dB/Octave)
Noise figure typ. < 7dB

Upstream
Frequency range 5…65 MHz
Gain 30 dB
Attenuation: adjustable in 1 dB steps 0…15 dB
Equalization interstage: pluggable with jumpers 0 | 3 | 6 | 9 dB
Attenuation interstage: pluggable with jumpers 0 | 6 dB

RF connectors
Type CFA 12-00/CKA 12-00
Test port at in-/output -20 ±2.5 dB/-20 ±1.0 dB

General
Switching power supply 30...65 VAC / 50...60 Hz
Power indicator LED
Power consumption 14 W
Equipotential bonding connection 4 mm²
Operating temperature range (acc. to EN 60065) -20…+50°C
Dimensions (W × H × D) appr. 182 × 146 × 71 mm
Weight 1.123 kg
IP code IP54